Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 
 








Motorize Auto Reset Meter
Motorize Auto Reset System - MARS

MARS provides the automatic reset for all the nuisance trip. In the event of power trip at remote power station, the MARS will reset automatically without physical attendance.

FEATURES

Automatic Reset:

  • Upon power trip, the power supply will cut off entirely. The power will the be restored immediately after automatic reset based on nuisance fault only.
  • The automatic reset timer can be scheduled different time range :

      Single Phase - 0 second, 1 minute, 30 minutes & 60 minutes
      Three Phase - 10 second, 30 second, 1 minute, 5 minutes, 10 minutes & 20 minutes.

Minimize maintenance cost:

 

  • Efficient way to auto reset all the nuisance trip. Hence reduce the operation cost.  

Application:

MARS can be fitted with circuit breakers in :

  • Power Cabinets (Secured with locks or password protection)
  • Telecommunication towers
  • Remote places


Safety aspect:

  • In the event of continuous fault or hard fault. The built-in intelligent system will detect the fault and STOP the automatic reset function.


Installation Site Examples :

MARS are mainly installed in outdoor Electrical Power Cabinets as shown by the picture below (Click to view pictures)

 

 

 

Motorize Auto Reset System (MARS) for 3-phase Motorize Auto Reset System (MARS) for 1-phase
Item Description
Rated Control Voltage AC380 to 440V
Rated Current 40A/ 60A/ 100A
Rated Sensitivity Current 100/ 200/ 500mA
Tripping Time 0.1 sec
Earth Leakage Tripping Device Solid State
Tripping Indicator Available
Frequency 50/ 60Hz +- 10% (only for control voltage AC specifications)
Alarm Output Contactt Capacity AC125V 0.5A DC30V 2A
Working Environment Temperature : 10 to 60 C with no freezing

Humidity : 45 to 85% with no dew condensation

Mecanical Switching Durability 10,000 times
Item Description
Rated Control Voltage AC240 to 260V
Rated Current 30A/ 40A/ 60A
Rated Sensitivity Current 30mA
Tripping Time 0.1 sec
Earth Leakage Tripping Device Solid State
Tripping Indicator Available
Frequency 50/ 60Hz +- 10% (only for control voltage AC specifications)
Alarm Output Contactt Capacity AC125V 0.5A DC30V 2A
Working Environment Temperature : 10 to 60 C with no freezing

Humidity : 45 to 85% with no dew condensation

Mecanical Switching Durability 10,000 times